DC/DC Converter
THL 25WI Series, 25 Watt
•
High power density 25W converter
Ultra compact design: 1.0” x 1.0” x 0.4”
•
Shielded metal case with isolated
baseplate
•
•
•
•
•
Ultra wide 4:1 input voltage ranges
•
•
I/O isolation voltage 1500 VDC
Very high efficiency up to 90%
UL 62368-1 IEC 62368-1
Output voltage adjustable
Remote On/Off control
Operating temp. range –40°C to +80°C
and up to +85°C with heat-sink
3-year product warranty
The THL 25WI series is a generation of DC-DC converter modules with high
power density. The product achieves 25 Watt output power and comes in a
metal case with small dimensions of only 1.0”x 1.0”x 0.4”. All models have a
wide 4:1 input voltage range and precisely regulated output voltages. High efficiency of up to 90% makes this product very reliable and applicable in temperature ranges of up to +80°C or up to +85°C with optional mounted heat sink.
Typical applications are in mobile equipments, instrumentation, distributed
power architectures in communication and industrial electronics and everywhere where space on the PCB is critical
Models
Order Code
Input Voltage
Range
THL 25-2410WI
THL 25-2411WI
THL 25-2412WI
THL 25-2413WI
THL 25-2422WI
THL 25-2423WI
THL 25-4810WI
THL 25-4811WI
THL 25-4812WI
THL 25-4813WI
THL 25-4822WI
THL 25-4823WI
9 - 36 VDC
(24 VDC nom.)
18 - 75 VDC
(48 VDC nom.)
Output 1
Output 2
Vnom
Imax
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
3.3 VDC
5 VDC
12 VDC
15 VDC
+12 VDC
+15 VDC
6'000 mA
5'000 mA
2'090 mA
1'670 mA
1'040 mA
840 mA
6'000 mA
5'000 mA
2'090 mA
1'670 mA
1'040 mA
840 mA
Vnom
Efficiency
Imax
–12 VDC
–15 VDC
1'040 mA
840 mA
–12 VDC
–15 VDC
1'040 mA
840 mA
typ.
87 %
89 %
89 %
90 %
89 %
89 %
88 %
90 %
90 %
90 %
89 %
89 %
Options
THL-HS1
- Optional Heat Sink: www.tracopower.com/products/thl-hs1.pdf
www.tracopower.com
November 9, 2023
Page 1 / 4
THL 25WI Series, 25 Watt
Input Specifications
Input Current
24 Vin models: 80 mA typ.
48 Vin models: 55 mA typ.
24 Vin models: 950 mA typ. (3.3 Vout model)
1'150 mA typ. (5 Vout model)
1'150 mA typ. (12 Vout model)
1'150 mA typ. (15 Vout model)
1'150 mA typ. (12 / -12 Vout model)
1'150 mA typ. (15 / -15 Vout model)
48 Vin models: 450 mA typ. (3.3 Vout model)
580 mA typ. (5 Vout model)
580 mA typ. (12 Vout model)
580 mA typ. (15 Vout model)
580 mA typ. (12 / -12 Vout model)
580 mA typ. (15 / -15 Vout model)
24 Vin models: 50 VDC max. (100 ms max.)
48 Vin models: 100 VDC max. (100 ms max.)
24 Vin models: 50 mAp-p typ.
48 Vin models: 30 mAp-p typ.
24 Vin models: 2'500 mA (slow blow)
48 Vin models: 1'250 mA (slow blow)
(The need of an external fuse has to be assessed
in the final application.)
Internal LC-Type
- At no load
- At full load
Surge Voltage
Reflected Ripple Current
Recommended Input Fuse
Input Filter
Output Specifications
Output Voltage Adjustment
Voltage Set Accuracy
Regulation
- Input Variation (Vmin - Vmax)
- Load Variation (0 - 100%)
Ripple and Noise
(20 MHz Bandwidth)
- Voltage Balance
(symmetrical load)
- Cross Regulation
(25% / 100% asym. load)
- single output
- dual output
Capacitive Load
- single output
- dual output
±10% (By external trim resistor)
See application note: www.tracopower.com/overview/thl25wi
Output power must not exceed rated power!
±1% max.
single output models: 0.2% max.
dual output models: 0.2% max.
single output models: 0.2% max.
dual output models: 1% max. (Output 1)
1% max. (Output 2)
dual output models: 2% max.
dual output models: 5% max.
3.3 Vout models: 100 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
5 Vout models: 100 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
12 Vout models: 150 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
15 Vout models: 150 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
12 / -12 Vout models: 150 / 150 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
15 / -15 Vout models: 150 / 150 mVp-p max. (w/ 1 µF MLCC || 10 µF
Tantalum)
3.3 Vout models: 10'300 µF max.
5 Vout models: 6'800 µF max.
12 Vout models: 1'200 µF max.
15 Vout models: 750 µF max.
12 / -12 Vout models: 680 / 680 µF max.
15 / -15 Vout models: 380 / 380 µF max.
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 9, 2023
Page 2 / 4
THL 25WI Series, 25 Watt
Minimum Load
Temperature Coefficient
Start-up Time
Not required
±0.02 %/K max.
30 ms max. (Power On)
30 ms max. (Remote On)
Continuous, Automatic recovery
150% typ. of Iout max.
118 - 125% of Vout nom.
(depending on model)
3.9 VDC typ. (3.3 Vout models)
6.2 VDC typ. (5.1 Vout models)
15 VDC typ. (12 Vout models)
18 VDC typ. (15 Vout models)
3% typ. / 5% max. (75% to 100% Load Step)
250 µs typ. (75% to 100% Load Step)
Short Circuit Protection
Output Current Limitation
Overvoltage Protection
Transient Response
- Response Deviation
- Response Time
Safety Specifications
Standards
CSA-C22.2, No. 60950-1
EN 62368-1
IEC 62368-1
UL 62368-1
www.tracopower.com/overview/thl25wi
- IT / Multimedia Equipment
- Certification Documents
EMC Specifications
EMI Emissions
- Conducted Emissions
- Radiated Emissions
External filter proposal:
EMS Immunity
- Electrostatic Discharge
Air:
Contact:
- RF Electromagnetic Field
- EFT (Burst) / Surge
Ext. input component:
- Conducted RF Disturbances
- PF Magnetic Field
Continuous:
EN 55032 class A (with external filter)
EN 55032 class A (with external filter)
www.tracopower.com/overview/thl25wi
EN 55024 (IT Equipment)
EN 55035 (Multimedia)
EN 61000-4-2, ±8 kV, perf. criteria A
EN 61000-4-2, ±6 kV, perf. criteria A
EN 61000-4-3, 10 V/m, perf. criteria A
EN 61000-4-4, ±2 kV, perf. criteria A
EN 61000-4-5, ±1 kV, perf. criteria A
KY 220 µF, 100 V, ESR 48 mOhm
EN 61000-4-6, 10 Vrms, perf. criteria A
EN 61000-4-8, 3 A/m, perf. criteria A
General Specifications
Relative Humidity
Temperature Ranges
- Operating Temperature
Power Derating
- Case Temperature
- Storage Temperature
- High Temperature
Cooling System
Remote Control
- Voltage Controlled Remote
(passive = on)
- Off Idle Input Current
- Remote Pin Input Current
Altitude During Operation
Switching Frequency
Insulation System
Isolation Test Voltage
- Input to Output, 60 s
- Input to Output, 1 s
95% max. (non condensing)
–40°C to +80°C
–40°C to +85°C (with Heat Sink)
+105°C max.
–50°C to +125°C
Depending on model
See application note: www.tracopower.com/overview/thl25wi
Natural convection (20 LFM)
On: 3.5 to 12 VDC or open circuit
Off: 0 to 1.2 VDC or short circuit
Refers to 'Remote' and '-Vin' Pin
3 mA typ.
-0.5 to 0.5 mA
6'000 m max.
285 kHz typ. (PWM)
Functional Insulation
1'500 VDC
1'800 VDC
All specifications valid at nominal voltage, resistive full load and +25°C after warm-up time, unless otherwise stated.
www.tracopower.com
November 9, 2023
Page 3 / 4
THL 25WI Series, 25 Watt
Isolation Resistance
Isolation Capacitance
Reliability
Washing Process
- Input to Output, 500 VDC
- Input to Output, 100 kHz, 1 V
- Calculated MTBF
1'000 MΩ min.
2'000 pF max.
444'000 h (MIL-HDBK-217F, ground benign)
According to Cleaning Guideline
www.tracopower.com/info/cleaning.pdf
Alu alloy, black anodized coating
Non-conductive FR4 (UL 94 V-0 rated)
Epoxy (UL 94 V-0 rated)
Copper Alloy (C6801)
Nickel (2.5 µm min.)
Gold (75 - 125 nm), glossy
Metal Case
PCB Mount
THD (Through-Hole Device)
1" x 1"
Lead-Free Wave Soldering
260°C / 10 s max.
16.5 g
- Case to Ambient
17.6 K/W typ.
14.8 K/W typ. (with Heat Sink)
www.tracopower.com/info/reach-declaration.pdf
REACH SVHC list compliant
REACH Annex XVII compliant
www.tracopower.com/info/rohs-declaration.pdf
Exemptions: 7a
(RoHS exemptions refer to the component
concentration only, not to the overall
concentration in the product (O5A rule).)
8cb0eff2-677a-444b-b63b-898d682a98b8
Housing Material
Base Material
Potting Material
Pin Material
Pin Foundation Plating
Pin Surface Plating
Housing Type
Mounting Type
Connection Type
Footprint Type
Soldering Profile
Weight
Thermal Impedance
Environmental Compliance - REACH Declaration
- RoHS Declaration
- SCIP Reference Number
Supporting Documents
Overview Link (for additional Documents)
www.tracopower.com/overview/thl25wi
2.54
25.4 (1.00)
10.16 (0.400)
10.16 (0.400)
(0.10)
Outline Dimensions
6.0
10.2 (0.40)
Pinout
(0.24)
Pin
3
4
5
Ø1.0
Bottom View
1
2
25.4 (1.00)
20.32 (0.800)
(Ø0.04)
Single
Dual
1
+Vin (Vcc)
+Vin (Vcc)
2
–Vin (GND)
–Vin (GND)
3
+Vout
+Vout
4
Trim
Common
5
–Vout
–Vout
6
Remote On/Off
Remote On/Off
6
5.08
7.62
2.5
(0.200)
(0.300)
(0.10)
Dimensions in mm (inch)
Tolerances: x.x ±0.5 (x.xx ±0.02)
x.xx ± 0.25 (x.xxx ±0.01)
Pin tolerances: x.x ±0.05 (x.xx ±0.002)
© Copyright 2023 Traco Electronic AG
Specifications can be changed without notice.
www.tracopower.com
Rev. November 9, 2023
Page 4 / 4
很抱歉,暂时无法提供与“THL 25-4823WI”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+923.315031+114.53680
- 5+892.525725+110.71740
- 25+831.0381825+103.08990
- 100+809.90469100+100.46830
- 国内价格 香港价格
- 1+581.688121+72.15814
- 10+495.4295810+61.45781
- 25+479.0727825+59.42876
- 50+467.0573350+57.93825
- 100+455.34349100+56.48515
- 250+400.48956250+49.68055